Medical Devices

Image

Multi Parameter Patient Monitor (Vital Signs Monitor) TD-2300

  • 5 Parameters – ECG, NIBP, SpO2, Ear Temperature and Blood Glucose measurement
  • Nellcor SatSeconds (TM) alarm management technology
  • Suitable for adult, pediatric and neonatal patients
  • 7″ TFT color LCD touch screen
  • Available with bluetooth, Wi-Fi
  • Defibrillation proof
TD-2300 Multi Parameter Patient Monitor is designed to help you capture vital data of patients for continuous, interval and spot check. TD-2300 Multi Parameter Patient Monitor supports Bluetooth, Wifi connection and can be easily get fast and accurate readings.
NIBP
Cuff Pressure Range0-300 mmHg
Measurement Method Adult mode (Clever Inflation or Deflation)
Pediatric mode (Clever Inflation or Deflation)
Neonate mode (Deflation Only)
Pressure Accuracy±3 mmHg over full range
AutomaticCycles OFF, 5min, 10min, 15min, 30min, 1hr, 1.5hr, 2hr, 4hr
Pulse Rate Range30 - 240 bpm
Pulse Accuracy± 2% or ± 1 bpm when HR < 70 bpm
SpO2 Monitor
SpO2 Measuring Range35 - 100%
SpO2 Accuracy80 - 100%, ±2%; 70-79%, ±3%; <70%, no definition
Pulse Measuring Range30 -250 bpm
Pulse Range±1 bpm or ±1% when HR < 100 bpm
Measuring PrinciplesDual wavelength LED
AudioTone with each detected pulse; pitch varies with saturation
ECG Monitor
Vertical Scales 5, 10 mm/mV
Sweep Speed25 or 50 mm/sec (Selectable for Print out only)
DC Offset Correction± 300mV
Signal Sampling Resolution300 samples/sec (with 12-bit ADC)
Pulse Measuring Range 30 - 250 bpm
Pulse Accuracy±1 bpm or ±1% when HR < 100 bpm
Defibrillation ProofYes
Blood Glucose
Measurement Range10 - 600 mg/dL
InterfaceIrDA communicate with main unit
HCT Compensation0 - 70%
Blood Volume1 µL
EnzymeGDH-FAD
Ear Temperature
Measurement Type Ear Thermometer
InterfaceIrDA communicate with main unit
Measurement Range32°C - 43°C
Accuracy± 0.2° C
Mechanical
Dimension190 (L) x 190 (W) x 309 (H)mm
Weight2.5 Kg( including accessory and battery)
Mounting OptionRolling Stand and Wall Mount
Image

Blood Oxygen Saturation Monitor
TD-8201 

 
  • Oxygen saturation and pulse rate
  • PI (Perfusion Index) indicator
  • Shock resistance / alarm warning
  • Bluetooth communication
 

TD-8201 Blood Oxygen Saturation Monitor(Pulse Oximeter) features SpO2, pulse rate and Perfusion Index(PI) indicator.

The Perfusion Index(PI) indicator indicates the pulse strength on a 10-bar indicator.

It is intended for patients with poor lung function or having bad efficiency in gaseous interchange on the lung during no-motion condition.

TD-8201 Blood Oxygen Saturation Monitor or called Professional Pulse Oximeter is suitable for use in hospiital, clinical and long term care sites.

TD-8201 Blood Oxygen Saturation Monitor(Pulse Oximeter) supports Bluetooth connection.

Water-Resistance and shock-resistance for optimal protection in all conditions.

Ergonomic design provides simple, single-hand operation.

Pulse Oximeter
SpO2 Display Range0-100%
SpO2 Resolution1%
SpO2 Accuracy80-100%, ±2%; 70-79%, ±3%; <70%, no definition
SpO2 MethodDual Wavelength LED
Pulse Rate Measuring Range30 - 250 bpm
Pulse Rate Accuracy±1 bpm or ±1% whichever is grater
Mode of OperationContinuous
LED DisplaySpO2, HR, Pulse-Strength Bar
Status IndicateProbe Good, Battery Status
Data TransmissionBluetooth
Perfusion Index10-bar indicator
Alarm Range SettingSpO2 High/Low , Pulse Rate High/Low
Pulse Volume Adjust2 Level or Off
LED Light Adjust2 Level
Power SourceAA Alkaline Battery x 4
Battery Usage Life40 hours
Dimension140 (L) x 70 (W) x 32 (H)mm
Weight240g (with batteries)
Storage/Transportation Condition-20ºC-60ºC; below 95% RH, non-condensing
Operating Condition10ºC-40°C; below 95% RH, non-condensing
Degree of ProtectionType BF
Water-ResistanceAgainst Water Splash, IPX2
Mechanical Impact-ResistanceAgainst Repeat Impact from 1 M Height
EMC StandardEN60601-1-2
Safety StandardEN60601-1
Performance StandardISO 80601-2-61
Image

Fingertip Pulse Oximeter

TD-8255

  • Finger Type
  • Oxygen saturation and pulse rate
  • PI (Perfusion Index) indicator

TD-8255 Fingertip Pulse Oximeter (Blood Oxygen Saturation Monitor) supports Bluetooth connection.

Fingertip Pulse Oximeter (Blood Oxygen Saturation Monitor) features SpO2, pulse rate and readings could be uploaded to Healthy Check app.

Soft touch rubber helps enhance patient comfort.

Fingertip Pulse Oximeter normal range:

For healthy children and adults, normal oxygen saturation is in range of 95 to 100 percent.

Research mentioned that many people with COVID-19 have low oxygen levels and this is a life-threatening condition.

Please note that not everyone with a low oxygen level will have difficulty breathing and CDC recommends that you must regularly monitor the oxygen levels of COVID-19 patients.

For more informatoin, please visit the Centers for Disease Control and Prevention (CDC) website below.

CDC guidance on the Basics of Oxygen Monitoring and Oxygen Therapy during the COVID-19

Companion App for Fingertip Pulse Oximeter

The free  Healthy Check app  is designed for at-home monitoring and available for iOS and Android platform, and also allows patients to sync daily blood oxygen readings from the device to track their health at anytime.

Part No.TD-8255A(No Data Transmission) / TD-8255B(Bluetooth)
CommunicationBluetooth(TD-8255B)
Dimension63 (L) x 35 (W) x 32 (H) mm
Weight40g (without battery)
Heart Rate Range30 ~ 250 beats per minutes (bpm)
SpO2 Range0% ~ 100%
Accuracy (SpO2)80%~100% ±2 digits
MethodDual wavelength LED
Perfusion Index 5-bar indicator
Accuracy (Heart rate)±1 bpm or ±1% whichever is greater
Power Source2 x AAA
Time to power saving15 seconds after removing finger
BacklightLCD backlight
Operating Temperature10ºC ~ 40ºC
EMC StandardIEC60601-1-2
Safety StandardIEC60601-1
Performance StandardISO80601-2-61
Unit per Carton80
Net Weight per Carton11.2kgs
Gross Weight per Carton12.5kgs
Carton Size518 (L) x 423 (W) x 300 (H) mm

Ear Thermometer

TD-1107

  • Infrared Technology
  • Probe cover ejector
  • Dual-color backlight 
  • Bluetooth (TD-1107C)

TD-1107 Ear Thermometer measure temperature accurately and gives a reading in just one second.
Illuminated display with dual-colored indicator for Hi/Low and fever guidance.
Hygienic and disposable probe filter for medical applications.
TD-1107 Ear Thermometer provided with one-hand easy operation of probe filter attachment and ejection without touching probe filter directly to reduce cross contamination.
TD-1107 Ear Thermometer (Medical Tympanic Thermometer) supports Bluetooth connection.

Image
Measurement Range32.0°C (89.6°F) ~43.0°C(109.4°F)
Accuracy±0.2°C (±0.4°F) for the range of 35.0°C to 42.0°C (95°F to 107.6°F)
±0.3°C (±0.5°F) for the range of < 35.0°C (95°F) or > 42.0°C(107.6°F)
Operating Condition10°C to 40°C (50°F to 104°F), 95% RH or less non condensing
Storage/Transportation Condition-20°C to 60°C (-4°F to 140°F), 95% RH or less non condensing
Resolution0.1°C / 0.1°F
Measurement Units°C or °F Switchable
LCD Back Light
Probe Cover DetectorEquipped with Auto power-on function
Power sourceAA x 2 alkaline battery
Battery lifeAt Least 3000 Measurements
Memory Capacity10 Measurements
Power Saving1 minute
CommunicationBluetooth (optional)
Dimension150 (L) x 42 (W) x 56 (H) mm
Weight80 g
Units per Carton
Net Weight per Carton
Gross Weight per Carton
Carton Size

Our Office

Head Office

SUITE B4, KINDARUMA APARTMENTS, KINDARUMA RD, OFF RING RD KILIMANI, OFF NGONG ROAD, NAIROBI, KENYA

Uganda Branch

Plot 896 Damulira Barnard 1st Floor
Makerere Kavule,
P.O. Box 28447 GPO Kampala
Uganda.

Phone

+254 20 440 40 35 / 6
+254 723-205384

Uganda Branch:

+256 706 952 660.
+256 774 516 351

Emails

info@agomagroup.com
sales@agomagroup.com

Social Media